|
|
RUBIDIUM Power Suplly PT:
When working with electronics, you always need one basic thing, power. „Focus on essentials“ is the motto of this power supply series. The Alpermann +Velte RUBIDIUM SERIES power supply modules are great for powering all kind of different applications. The RUBIDIUM Power supply modules are available in four version, the internal built in RUBIDIUM modules PS, PT with 3HE (designed for use with our H3 housing) and PQ can power up to twelve modules at a time and offer failproof operation, when more than one module is inserted into a RLC connected system. All modules are universally implementable (110 V to 250 V) and have a built in overload protection. PE is useful for S1 and T1 housings.
Temperature and the power outputs can be monitored via an internal interface. Each module in the frame with an microprocessor on board (all RUBIDIUM generators and inserters) can decode the power supply information and is able to send the information via TC_link to the status monitor or to the IE module to allow SNMP functions.
|
Power Supply Features PT
60 Watts Power
110V - 250V universal compatible
Overload protection
Additional protection
Universal IEC locking inlet
Failure relay
„Hot swapping“ compatible
2-pole ON/OFF switch
2-pole-fuse-holder
Interface for voltage and temperature control
via status monitor or via IE - module
with SNMP control
|
|
|
|
|
TC_link is an Alpermann + Velte standard protocol for data transfer via a modified RS 485 interface.
Input RUBIDIUM Power supplies PT specifications
|
Inlet socket
|
|
According to IEC/EN 60320-1/C14, protection class1
|
|
Line voltage range
|
|
90-132 / 180-264 VAC, auto-ranging
|
|
Power line frequencey
|
|
47-63 Hz
|
|
Input current
|
|
800 mA maximum at 90 VAC
|
|
Efficiency
|
|
83% at full load, 25°C, 230 VAC, after 5 min. warm up
|
|
Line regulation
|
|
+/- 0,5 %
|
Output RUBIDIUM Power supplies PT
|
Output voltage / current
|
|
23.7 VDC ± 5%/1.05 A minimum, 2,5 A maximum
|
|
Turn-on delay
|
|
4 secs maximum
|
|
Ripple + Noise
|
|
240mV maximum
|
|
Load regulation
|
|
± 1% maximum
|
|
Overload protection
|
|
Typically at 130% of max. current, automatic recovery
|
|
Temperature coefficient
|
|
2,4 mV/°C
|
|
Hold-up time at 100% load
|
|
10ms
|
Miscellaneous PT
|
Weight PT
|
|
0.5 kg
|
|
Dimensions mechanical (circuit board) PT
|
|
(WxD): 100x160mm / 3.94x 6.30 inch
|
|
Dimensions mechanical rear panel PT
|
|
103x44 mm/4.06x 6.30 inch
|
|
Enviromental characteristics, operating
|
Ambient temperature if plugged to RUB series 1
frame: +5°C to +40°C,
relative humidity: 20-80% non-condensing
|
|
Enviromental non-operating
|
|
Temperature:-30°C to +70°C, relative humidity:5%-95% non-condensing
|
|
Altitude
|
|
Operating at 3000m / 10.000ft maximum
|
Product ordering ID: RUB 3 PT
|
Module description PT
|
|
Power supply for H3 housing
|
|
Functional description PT
|
|
60 W power supply
|
We reserve the right to modify specifications without notice.
|