products Abstand Rubidium Series 1 & 3:
Module SL
Abstand Alpermann+Velte

Leaflet:
pdf-file

Manual:
pdf-file.... zip- file

Abstand
SR button Housing
H1-Module in a 19"/1 RU-Housing




RUBIDIUM Series 1 & 3, Module SL:



Features
Switcher for LTCsignals
Signal monitor with status indicator
GPI outputs for error indication
Optional SNMP and status indication via internet browser
Bi-stable signal outputs relays

The Alpermann+Velte Rubidium SL module is an automatic switchover unit for LTC signals. It analyzes and monitors two LTC sources. If one LTC source is lost, the LTC output is automatically switched to the other error free source. Connected to a reference time source, the LTC signal is monitored and analyzed in conjunction with this reference time. The module offers a monitor function for errors in the LTC, errors in the reference time source, for time differences between the two individual LTC sources, and for the status information of all input sources.

When a SL module is combined with two of our master generators RUB GT or RUB GL, a fully redundant fail-safe LTC generator system can be established. One or both LTC input sources can also be acquired from external non Alpermann+Velte devices as long as the LTC signal complies with the SMPTE/EBU format rules.

SL
In the event of a failure the signals can be switched automatically or manually. The changeover is completed with bistable relays. The relay contact remains in its last position if power is lost. The relays are mounted on a separately installed circuit board, so that even when physically exchanging a module, the signal flow can continue without interruption.

Circuit Diagram

LEDs located on the front of the module indicate the operating status. Built-in GPIs can be programmed to signal errors or other pre-programmed warnings. The backlit keys on the front of the module can be programmed to suit the user specific needs (e.g. a key could be programmed to manually switch incoming sources). Also available are distribution amplifier modules with four separate outputs, or six fail-safe amplified outputs specifically designed for redundant systems.

Front
SL Front View
SL


All programmable functions and the communication between modules are handled with the included configuration software. The operating status of the module is available at any time via a status monitor function. The status request is made using a PC software via the USB interface of the applicable housing (H1, H3, S1, T1). The firmware or additionally purchased options are installed via the same USB interface.

With an additional Ethernet module (RUB IE), a standard web browser can access all status information and configuration menus. Monitoring via SNMP is also possible.

Browser
Browser Configuration


Rubidium Config
Rubidium Configuration

SL Draw H1 rear Rear Panels Rubidium 1 (left) & 3 (right) SR Draw H3 rear

Specifications SL module

LTC/MTD IN (2xRJ45)
RS 485
Balanced in- or outputs of a RS485 serial interface
Format
ANSI/SMPTE 12M-1999, balanced
Signal Level
100 mVp-p to 5 Vp-p, auto-ranging
Input Impedance
18 kΩ
Frequency
19 - 33 Frames per second
SERIAL IN
Serial time and date string
TELEGRAM IN
Impulse telegram

LTC/MTD OUT (RJ45 and DSUB9F)
RS485
RS485 serial interface, hard-wired with signals at LTC/MTD IN
LTC OUT
Balanced LTC output, switched via relay to one input
SERIAL OUT
Serial time and data string, switched via relay to one input
TELEGRAM OUT
Impulse telegram, switched via relay to one input

REF IN (RJ45)
PPS IN
Pulse per second, input
RXD IN
Reference time and date input, serial data string

REF OUT (2 x RJ45)
PPS OUT
Pulse per second output, hard-wired with signal at REF IN
TXD OUT
Reference time and date output, hard-wired with signal at REF IN

GPI OUT (RJ45)
FAIL
Failure Signals
WARNING
Warning Signals

Others
Operating Voltage
12 - 30 VDC
Power consumption
max 1.2 W
Weight
0.3 kg approx.
Dimensions Rub H1
2 circuit board (W x D): 100 x 160 mm
/ 3.94 x 6.30 inch
Rear panel: 103 x 44 mm / 4.06 x 1.73 inch
Dimensions Rub H3
Rear panel: 3RU, 8HP
Environmental characteristics, operating
Temperature: +5 °C - +40 °C
Relative humidity: 30 % - 85 %, non-condensing
Environmental characteristics, non-operating
Temperature: -10 °C - +60 °C
Relative humidity: 5 % - 95 %, non-condensing

Product ordering ID SL modules
RUB1 SL
LTC/RS485 changeover unit and monitoring module (1RU)
RUB3 SL
LTC/RS485 changeover unit and monitoring module (3RU)



Legend:
LTC:
Linear Time Code (SMPTE 12M-1999)

The RUBIDIUM modules must be used in conjunction with a RUBIDIUM housing and a RUBIDIUM power supply, please see our overview leaflet for more information.

We reserve the right to modify specifications without notice.

Erde Abstand Englisch home ueber uns Inhalt
Produkte Service Projekte FAQ
sales Email Imprint
© Alpermann+Velte 1996 - 2010; June 22, 2010